4 INTRODUCTION GENERAL PRECAUTIONS The following list includes general precautions to remember when handling the StratosH. DO NOT TURN the u
5 INTRODUCTION MS2320 SCANNER/SCALE DESIGN SPECIFICATIONS Design Specifications Operational Light Source: VLD 650 nm Peak Laser Power: <2
6 BASE MODEL CHARACTERISTICS MS2320 Scanner/Avery Scale Components Figure 8. MS2320 Components ITEM NO. DESCRIPTION OF ITEM 1 Blue and Wh
7 BASE MODEL CHARACTERISTICS MS2320 Scanner/Avery Scale Dimensions Figure 9. MS2320 Dimensions Connector Panel Figure 10. MS2320 Connec
8 BASE MODEL CHARACTERISTICS MS2320 Scanner/Avery Scale Caution and Serial Number Labels Figure 11. MS2320 Label Locations (Top) and Examples
9 INSTALLATION QUICK INSTALLATION OUTLINE The following is a quick preview of the steps required for first time installations. Each item is dis
10 INSTALLATION QUICK INSTALLATION OUTLINE Power Installation The Power Supply (AC/DC) should be connected to an AC Outlet that is free of ele
11 INSTALLATION UNPACKING THE UNIT 1. Make sure the shipping box is top-side up before opening. 2. Remove the accessories box and check
12 INSTALLATION UNPACKING THE UNIT MS2320 Package Warning All hardware securing the scale arms during shipping must be removed or the scale wil
13 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2320 Mounting Diagram (Two Point Support) Figure 18. MS2320 Mounting Diagram, Two Point Su
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this documen
14 INSTALLATION INSTALLING THE UNIT IN THE COUNTER MS2320 Mounting Diagram (Three Point Support) Figure 19. MS2320 Mounting Diagram, Three Poi
15 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 The following steps describe how to properly install the cables for an RS232 Strat
16 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 9. Turn on the host system. 10. Scan the Recall Defaults bar code. The Recall
17 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB The following steps describe how to properly install the cables for a Full
18 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) FULL SPEED USB 9. Turn on the host system. 10. Configure the StratosH to match the hos
19 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) xxx* Specifies international connection. See page 3 for a complete listing of power
20 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS485 The following steps describe how to properly install the cables for an RS485 Strato
21 INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS485 9. Turn on the host system. 10. Configure the StratosH to match the host system’
22 INSTALLATION CABLE INSTALLATION (SECONDARY HONEYWELL SCANNER) The following steps describe how to properly install the cables between a seconda
23 INSTALLATION CABLE INSTALLATION (SECONDARY HONEYWELL SCANNER) † See Aux power notes on page 22 See power source caution statement on page
ii TABLE OF CONTENTS INTRODUCTION Manual Scope ...
24 INSTALLATION EAS DEACTIVATION SW1 and SW2 are the switch banks inside the Checkpoint device that set the deactivation range. The following is
25 SCANNER OPERATION SCAN ZONE Figure 26. Checker-Side (13 mil) Figure 27. Horizontal Left/Right (13 mil) Specifications are subject to ch
26 SCANNER OPERATION SCAN ZONE Figure 28. Horizontal Direct (13 mil) Figure 29. Vertical Direct (13 mil) Specifications are subject to c
27 SCANNER OPERATION IR ACTIVATION AREA (IR LED OUTPUT) The StratosH’’s default power save mode† is Dual Action Power Save Mode #2 (see page 32).
28 Figure 31. LEDs SCANNER OPERATION INDICATOR DESCRIPTIONS Audible When in operation, the StratosH provides audible feedback that indicates th
29 SCANNER OPERATION INDICATOR DESCRIPTIONS Visual Steady White and Blue After a successful scan, the scanner transmits the data to the host de
30 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display There is a two-digit error code display located under the platter near
31 SCANNER OPERATION INDICATOR DESCRIPTIONS Diagnostic Indicator Display ERROR CODE DESCRIPTION 11 SWITCH ERROR – The switch used for volume se
32 SCANNER OPERATION POWER SAVE MODES The StratosH has five configurable power save modes. Refer to the MetroSelect Configuration Guide (PN 00-0
33 SCANNER OPERATION BEEPER OPTIONS AND BUTTON FUNCTIONS Changing the Beeper Tone Beeper tones may be configured incrementally using the followin
iii TABLE OF CONTENTS Keyboard Emulation Mode ...
34 SCANNER OPERATION STARTUP When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep
35 SCALE OPERATION SCALE ZEROING After the unit has been officially calibrated (see page 36) the scale can be re-zeroed by pressing the scale zer
36 SCALE OPERATION CALIBRATION The scanner/scale must be calibrated if: • it is a first time installation • the scale cannot be re-zeroed • t
37 SCALE OPERATION CALIBRATION Priming the Scale for Calibration Prime the scale before starting either method of calibration. Calibrate the s
38 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 1. Temporarily remove the platter and place it in
39 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 5. Enter calibration mode. The remote display wi
40 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display 9. Place a half load (15.00 lbs. or 7.500 kg) on th
41 SCALE OPERATION CALIBRATION Scale Calibration Procedure (lbs. or kg) with Remote Display* 14. The unit’s calibration must now be verified a
42 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* The following calibration procedure can be used when th
43 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 5. Reinstall the platter and power up the unit.
iv TABLE OF CONTENTS MAINTENANCE Platter / Horizontal Scan Window Replacement ...
44 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 9. Place a half load on the center of the scale platter
45 SCALE OPERATION CALIBRATION Bar Code Calibration Procedure without Remote Display* 13. Calibration is now complete. The scanner will auto
46 SCALE OPERATION CALIBRATION VERIFICATION U.S. Pounds (lbs.) The following tests verify if the scale's Calibration is accurate. For Kilo
47 SCALE OPERATION CALIBRATION VERIFICATION Kilograms (kg) The following tests verify if the scale's Calibration is accurate. For US Pou
48 SCALE OPERATION SECURITY SEAL INSTALLATION The certification of the weighing mechanism of the scale version of this scanner is subject to fed
49 SCALE OPERATION SECURITY SEAL INSTALLATION Wire Security Seal (Seal Conversion Kit 46-46890)* 1. Temporarily remove the platter and place
50 MAINTENANCE PLATTER / HORIZONTAL SCAN WINDOW REPLACEMENT Figure 68. Platter/Horizontal Scan Window Replacement* * See replacement par
51 MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT (PN 46-46889) Figure 69. Vertical Scan Window Replacement DAILY MAINTENANCE Smudges and
52 TROUBLESHOOTING The following guide is for reference purposes only. Contact a customer service representative to preserve the limited warranty
53 TROUBLESHOOTING Symptom Possible Cause(s) Solution All Interfaces Scanner beeps at some bar codes and NOT for others of the same bar code sym
54 SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS The StratosH scanner terminates to 10-pin modular jacks located on the bottom of th
55 SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS Figure 71. Scale Data (Dual Cable Applications) and Scale Display Connector Layout
56 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS The following cables are examples of some of the standard cables that may be sh
57 SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS Aux Port Configuration Cable*, PN 57-57008x-N-3 Pin Function** 9-Pin D-Type Co
58 REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 C
59 REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Note: Immunity performance is not
60 REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s auth
61 LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mater
62 PATENTS For patent information, please refer to www.honeywellaidc.com/patents.
63 INDEX A AC ... see power application ...
1 INTRODUCTION MANUAL SCOPE This guide provides information on the installation, setup and operation of Honeywell’s StratosH®, MS2320 scanner/Av
64 INDEX scanner pinouts ... 54–57 seal ...
65 CUSTOMER SUPPORT TECHNICAL ASSISTANCE If you need assistance installing or troubleshooting your device, please call your distributor or the ne
66 CUSTOMER SUPPORT PRODUCT SERVICE AND REPAIR Honeywell International Inc. provides service for all its products through service centers through