Page 1 - Installation and User’s Guide

METROLOGIC INSTRUMENTS, INC.MS7120 Orbit® PresentationLaser ScannerInstallation and User’s Guide

Page 2

6INSTALLATION FOR STAND ALONE KEYBOARD INTERFACE1. Turn off the host system.2. Plug the male 10-pin RJ45 end ofthe PowerLink cable into the10-pin ja

Page 3 - LOCATIONS

7INSTALLATION NOTES FOR USB INTERFACEMetrologic’s MX009 USB cable is a device that converts serial RS232formatted data to either USB Keyboard or USB P

Page 4 - TABLE OF CONTENTS

8SCANNER PARTSRed LEDOn a successful read of a bar code, the red LED will turn ON.After communication to the host is complete, the red LED willturn OF

Page 5 - INTRODUCTION

9AUDIBLE INDICATORSWhen the MS7120 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight sett

Page 6 - SCANNER AND ACCESSORIES

10VISUAL INDICATORSThere is a red LED and a green LED on the head of the MS7120. Whenthe scanner is on, the flashing or constant illumination of the L

Page 7 - OPERATIONAL NOTES

11FAILURE MODESFlashing Green and One Razzberry ToneThis indicates the scanner has experienced a lasersubsystem failure. Return the unit for repair a

Page 8 - 6. Turn on the host system

12LABELSEach scanner has three labels on the bottom of the unit. These labelscontain information such as; the model number, date of manufacture,seria

Page 9

13SCAN VOLUME SPECIFICATIONSSpecifications based on 100% UPC Bar Codes.Optimal Low Density (Default)Optimal High Density190mm60mm100mmScan Area215mm10

Page 10 - Caution:

14SCAN VOLUME SPECIFICATIONS (CONT.)Specifications based on 100% UPC Bar Codes.CloseNormal95mm175mmScan Area60mmScan Area190mm60mm100mm

Page 11 - Enable Laser Emulation Mode

15SCAN VOLUME SPECIFICATIONS (CONT.)Specifications based on 100% UPC Bar Codes.Far215mmScan Area75mm75mm105mm

Page 13 - AUDIBLE INDICATORS

16DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTHOptimal Low Density (Default)Distance:Scanner FaceTo Bar Code(mm)Width of Scan Field (mm)Minimum Bar

Page 14 - VISUAL INDICATORS

17DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTHOptimal High DensityDistance:Scanner FaceTo Bar Code(mm)Width of Scan Field (mm)Minimum Bar Code Ele

Page 15 - FAILURE MODES

18DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTHCloseDistance:Scanner FaceTo Bar Code(mm)Width of Scan Field (mm)Minimum Bar Code Element WidthBCDEF

Page 16 - MAINTENANCE

19DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTHNormalDistance:Scanner FaceTo Bar Code(mm)Width of Scan Field (mm)Minimum Bar Code Element WidthABCD

Page 17 - SCAN VOLUME SPECIFICATIONS

20DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTHFarDistance:Scanner FaceTo Bar Code(mm)Width of Scan Field (mm)Minimum Bar Code Element WidthABCDEFG

Page 18

21INSTALLING THE OPTIONAL WALL/COUNTER MOUNTKit #45-45619 contains:a. Locking Plate[MLPN 50-50302] ... Qty. 1b. Base Cover[ML

Page 19

22TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Page 20 - Optimal Low Density (Default)

23TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit powersup, but doesnot scan and/orbeepBeeper disabled. Notone selectedEn

Page 21 - Optimal High Density

24TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanner beepsat some barcodes and NOTfor others of thesame bar codesymbologyThe

Page 22

25TROUBLESHOOTING GUIDE (CONTINUED)Keyboard Wedge OnlySYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit scansthe bar codebut there is nodataConfiguration is

Page 23

iiLOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo

Page 24

26TROUBLESHOOTING GUIDE (CONTINUED)RS-232 OnlySYMPTOMS POSSIBLE CAUSE(S) SOLUTIONPower-up OKand scans OKbut does notcommunicateproperly to thehostCom

Page 25 - Kit #45-45619 contains:

27RS-232 DEMONSTRATION PROGRAMIf an RS-232 scanner is not communicating with your IBM compatible PC, keyin the following BASIC program to test that th

Page 26 - TROUBLESHOOTING GUIDE

28APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number andfactory default communications protocol.SCANNERVERSIONIDEN

Page 27

29DESIGN SPECIFICATIONSMS7120 SPECIFICATIONSOPERATIONALLight Source: VLD 640-660 nmDepth of Field: 0 mm to 190 mm (0" to 7.5") at default (p

Page 28

30DESIGN SPECIFICATIONSMS7120 SPECIFICATIONSELECTRICALInput Voltage: 5.2VDC ± 0.25VPower: 1.1 WOperating Current: 220 mA (270 IBM)DC Transformers: Cl

Page 29

31DEFAULT SETTINGSMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the factory

Page 30 - MLPN 00

32DEFAULT SETTINGSParameter Default OCIA RS-232*LightPenIBM46XXKBWLaserEmulationDTS/NIXDORF*üNCR FüNCR SüPoll Light Pen SourceüBeeper Tone Normalüüüüü

Page 31 - RS-232 DEMONSTRATION PROGRAM

33DEFAULT SETTINGSParameter Default OCIA RS-232*LightPenIBM46XXKBWLaserEmulationConvert EAN-8 to EAN-13üü üüTransmit UPC-A NumberSystem*üüüüü üTransmi

Page 32 - APPLICATIONS AND PROTOCOLS

34DEFAULT SETTINGSParameter Default OCIA RS-232*LightPenIBM46XXKBWLaserEmulationCarriage Return*üüLine Feed - disabled bydefault in KBW*üüTab Prefixüü

Page 33 - DESIGN SPECIFICATIONS

35DEFAULT SETTINGSParameter Default OCIA RS-232*LightPenIBM46XXKBWLaserEmulationCoupon Code 128üüascode39üüas code39Programmable CodeLengths7 avail.üü

Page 34

iiiTABLE OF CONTENTSIntroduction...1Scanner and Accessori

Page 35 - MULATION

36110SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsThe MS7120 scanner interfaces terminateto a 10-pin modular jack. The serial # labelindica

Page 36 - EFAULT SETTINGS

37SCANNER AND CABLE TERMINATIONSMS7120-11 IBM 46XX/RS-232Pin Function1 Ground2 RS-232 Transmit Output3 RS-232 Receive Input4 RTS Output5 CTS Input6 DT

Page 37

38SCANNER AND CABLE TERMINATIONSCable Connector ConfigurationThe PowerLink cable is terminated with a 5-pin DIN female connector onone end, and a 6-pi

Page 38

39LIMITED WARRANTYThe MS7120 Orbit© scanners are manufactured by Metrologic at its Blackwood, New Jersey,U.S.A. facility. The MS7120 scanners have a t

Page 39

40NOTICESNoticesThis equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC rules.

Page 40 - CANNER AND CABLE TERMINATIONS

41NOTICESAchtungDie Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungenoder Verfahren kann eine gefährliche Laserstrahlung hervor

Page 41 - 54-54020

42NOTICESDie nachfolgende Mitteilung gilt nur für Modell Nr. MS7120-11Zur Klassifizierung gemäß Klasse B nach FCC Teil 15, ICES-003 und EN55022,befest

Page 42 - Cable Connector Configuration

43NOTICESNota (exclusivamente para los modelos de la serie MS7120-11)De acuerdo con las normativas FCC apartado 15, ICES-003 y EN55022 para laClase B,

Page 43 - LIMITED WARRANTY

44PATENTS “Patent InformationThis METROLOGIC product may be covered by one or more of the followingU.S. Patents:U.S. Patent No.;4,960,985; 5,081,342;

Page 44

45INDEXAaccessories... 2, 3adapter... 2, 3, 5, 38application... 27audible ...

Page 45 - Figure 1

1INTRODUCTIONOrbit® is an aggressive, omnidirectional laser bar code scanner. Lightweight and rugged, Orbit is small in size, but BIG in performance.

Page 46 - Figura 1

46INDEXNnormal depth of field... 35notices ... 40, 41, 42, 43OOCIA...1-4, 28, 29, 31-36omnidirectional...

Page 48

July 2003Printed in USA 00 -02408B

Page 49

2SCANNER AND ACCESSORIESBASIC KITPart # DescriptionMS7120 Orbit® Presentation Laser Scanner00-02407 MetroSelect® Programming Guide00-02408 MS7120 Ins

Page 50

3SCANNER AND ACCESSORIESOPTIONAL ACCESSORIESPart # DescriptionMVC**Metrologic Voltage Converter Cable+12VDC to +5.2VDC or -12VDC to +5.2VDCMX009-2** M

Page 51

4INSTALLATION FOR RS232, OCIA AND IBM 46XX INTERFACES1. Turn off the host system.2. Plug the male 10-pin RJ45 end ofthe PowerLink cable into the 10-

Page 52 - 00 -02408B

5INSTALLATION FOR KEYBOARD WEDGE INTERFACE1. Turn off the PC/Host.2. Connect the male 10-pin RJ45 end ofthe PowerLink cable to the jack onthe MS7120