SCANNER AND CABLE TERMINATIONS
CABLE CONNECTOR CONFIGURATIONS
Aux Port Configuration Cable*, MLPN 57-57008x-N-3
Pin Function**
1
No Connect
2 Output from Scanner
3 Input to Scanner
4
No Connect
5 Ground
6-9
No Connect
9-Pin D-Type Connector
RS232 LSO/AUX Cable, MLPN 57-57099x-3
Pin Function
1 Signal Ground
2 RS232 from Aux / Secondary Scanner
3 RS232 to Aux / Secondary Scanner
4 RTS from Aux / Secondary Scanner
5 CTS to Aux / Secondary Scanner
6-8
No Connect
9 + 5VDC – Transformer / Direct
10 Shield Ground
10-Position Modular Plug
* This configuration cable was designed to be used with the StratosS auxiliary connector only.
** All signals are referenced from the StratosS scanner.
All signals are referenced from the auxiliary / secondary scanner.
Specifications are subject to change without notice.