Prefixes/Suffixes
E
21
SECTION E CHARACTER REPLACEMENTS
To replace a character:
1. Scan the Enter/Exit Configuration Mode bar code
(located on page x, at the front of this guide)
2. Scan the Character to Replace Code (shown below)
3. Scan the ASCII Code Byte value of the character you with to replace.
(refer to the ASCII reference table in Section M)
4. Scan the Replacement Character bar code
5. Scan the ASCII Code Byte value of the replacement character.
6. Scan the Enter/Exit Configuration Mode bar code.
(located on page x, at the front of this guide)
Character to Replace No Replacement
³938600 ³838600
Replacement Character
³938700