Metrologic StratosS MS2220 Guide de l'utilisateur Page 52

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 88
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 51
46
SCALE OPERATION
CALIBRATION
Scale Calibration Procedure (lbs. or kg) with Remote Display
7. Make sure there is no load on the scale platter.
8. Calibrate a zero load. Press the right arrow () button once when the remote display reads CAL 1 and there is no load
on the scale platter.
Figure 44.
9. Place a half load (15.00 lbs. or 7.500 kg) on the center of the scale platter then press the right arrow () button.
Figure 45.
10. Add an additional half load (15.00 lbs. or 7.500 kg) to the existing half to simulate a full load, center entire load then press
the right arrow () button.
Figure 46.
11. Remove half of the load (15.00 lbs. or 7.500 kg), center the remaining load then press the right arrow () button.
Figure 47.
Vue de la page 51