DESIGN SPECIFICATIONS
ELECTRICAL
Input Voltage: 5VDC ± 0.25V
Power: Operating = 0.825 W, Standby = 0.600 W
Current:
Operating = 165 mA @ 5VDC,
Standby = 120 mA @ 5VDC
DC Transformers: Class 2; 5.2V @ 650 mA
Laser Class: CDRH: Class II; EN60825-1:1994/A11:1996 Class 1
EMC: FCC Class B
ENVIRONMENTAL
Temperature:
Operating = 0°C to 40° (32° to 104°F)
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Light Levels: Up to 4842 Lux (450 footcandles)
Shock: Designed to withstand 1.5 m (5’) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
Specifications subject to change without notice.