INDICATORS
Visual
Steady Red, Green* off
This indicates the scanner may be waiting for communication from
the host.
Failure Modes
Flashing Green* and one Razzberry Tone
This indicates the scanner has experienced a laser sub-system
failure. Return the unit for repair to an authorized service center.
Flashing Red* and Green* with Two Razzberry Tones
This indicates the scanner has experienced a scanning
mechanism failure. Return the unit for repair to an authorized
service center.
Continuous Razzberry Tone with all LEDs off
If, upon power, the scanner emits a continuous razzberry tone,
then the scanner has an experienced an electronic failure. Return
the unit for repair to an authorized service center.
Three Beeps – on power up
If the scanner beeps 3 times on power up then the non-volatile
memory (NovRAM) that holds the scanner configuration has
failed. If the scanner does not respond after reconfiguring, return
the scanner for repair to an authorized service center.
* In some custom units the standard green LED has been replaced with a blue LED and
the red LED has been replaced with a white LED.