10
MOUNTING SPECIFICATIONS
Enclosure Specifications
Minimum Allowable Window Position
Required To Avoid Detrimental Internal Reflective Beam Interference
at Negative Exit Beam Angle Tolerance
Figure 7.
Exit Beam
Depression Angle β
Minimum Projected Distance
from the Engine’s Base to the
Window’s Internal Surface (M)
Minimum
Window Angle θ
-2.5° 5.0 23.5°
-2.5° 10.0 16.5°
-2.5° 15.0 12.5°
-2.5° 20.0 10.5°
-2.5° 25.0 9.0°
-2.5° 30.0 8.0°
-2.5° 35.0 7.5°
-2.5° 40.0 7.0°
-2.5° 45.0 6.5°
-2.5° 50.0 6.0°
Specifications are subject to change without notice.